Wolfvision VZ-15b User Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Videokamery Wolfvision VZ-15b User Manual. WolfVision VZ-15b User Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - VZ-15b / VZ-35b / VZ-45b

INSTRUCTIONSVZ-15b / VZ-35b / VZ-45bENGLISHR

Strany 2 - PRECAUTIONS

AUTOIRIS / MANUAL IRIS (all Visualizers)WolfVision Visualizers are equipped with autoiris. That means that the brightness of the camera image adjusts

Strany 3 - CONTENTS:

VIDEO RECORDING (VZ-15b and VZ-35b only)video / Y/C outvideo / Y/C inVCR "stop"video / Y/C invideo / Y/C outSWITCHING TO PLAYBACK OF A VIDEO

Strany 4 - CONTROL PANEL

SCANNING SLIDE SHOWS (all Visualizers)VisualizerSlide projectorA combination of a WolfVision Visualizer and one or more slide projectors allows easy s

Strany 5

If the unit gets too hot (when ventilation or air extraction are covered) a built in thermostat may switch off the light of the Visualizer. Lay open t

Strany 6

TRANSPORTATION (all Visualizers)IMPORTANTIMPORTANTFor transportation press the release button for the arm (#11) and at the same time push the arm down

Strany 7

WHITE BALANCE ADJUSTMENT (all Visualizers)TEXT ENHANCEMENT (VZ-45b and VZ-35b only!)FREEZE FUNCTION (VZ-45b only!)Each time the lighting condition cha

Strany 8

SETTINGS WHICH CAN BE CHANGED IN THE CAMERA MENU of VZ-35b:GAINThe video gain level can be set in the range of 0 to 18 dB in units of 1dB.SHUTTERThe e

Strany 9

2. Color Setup menu (of VZ-35b):C.TEMP (COLOR TEMPERATURE)Selects the color temperature accordance to the lighting. Use 3200K for indoor shooting and

Strany 10 - (all Visualizers)

EXTERNAL SYNCHRONIZATION OF THE VISUALIZER (VZ-35b)professional video mixerprofessional video cameracomposite video / Y/C signalBB / sync signalINOUT

Strany 11 - (VZ-15b and VZ-35b only)

SETTINGS WHICH CAN BE CHANGED IN THE CAMERA MENU of VZ-45b:GAIN1. Exposure Setup menu (VZ-45b only):SHUTTERYou can change between following settings:A

Strany 12 - (all Visualizers)

Make sure that sufficient air circulation for cooling the unit is possible (ventilation slots on the left and right side of the unit) If the Visualize

Strany 13

SPECIFICATIONSPick-up element / video VZ-15b VZ-35bBuilt-in camera system3 CCD un

Strany 14 - IMPORTANT

SPECIFICATIONSPick-up element / video VZ-45b Built-in camera system3 CCD unit - 1/2" interline transfer Effective pixel

Strany 15

TROUBLESHOOTINGSymptoms: Check points:No power - Is a power cord connected?- Is the main power switch (# 34, on the back of the unit) switched to &quo

Strany 16 - (VZ-35b only)

Symptoms: Check points:The lightfield on the working surface is much larger than the recorded area. Please note that the lightfield has to be a littl

Strany 17

24Airflow inputAirflow outputAbluftZuluft5 mm16 mm17 mm23 mm28 mm34 mm38 mm64 mm120 mm122 mm172 mm176 mm180 mm185 mm210 mm408 mm450 mm565 mm598 mm650

Strany 18 - (VZ-45b only!)

1235678910111413412Codes:Reflectionfree area1235678910111413412Codes:Reflectionfree areaPrinted in Austria - February 1998RZOOMFOCUSIRISIMAGELIGHTPRES

Strany 19

CONTENTS:Manufacturer: Wolf Vision GmbH & Co KG, Vlbg. Wirtschaftspark, A-6840 Götzis / AUSTRIA, Tel. ++43/5523/52250-0, Fax. ++43/5523/52249, E-

Strany 20 - SPECIFICATIONS

ZOOMFOCUSIRISIMAGELIGHTPRESETPOWERoffonR#1 Arm with pneumatic damper#2 Mirror system#3 Control panel#4 Connections (on the back)#5 Working p

Strany 21

#31 Preview video output #32 Composite video output #33 External Sync Input (Genlock)#34 Main power switch#35 Fuse (see page 14)#36 Power connec

Strany 22 - TROUBLESHOOTING

#34 Main power switch#35 Fuse (see page 14)#36 Power connection#38 Serial port for external remote controlling#39 Parallel port for external remo

Strany 23 - Symptoms: Check points:

HOW THE VISUALIZER WORKS (all Visualizers)baA light projector (b) inside the WolfVision Visualizer projects the light via a mirror inside the unit and

Strany 24 - Airflow output

1. Place your subject material on the working surface. For background use either the white side or the black side of the working plate. For some o

Strany 25

REFLECTIONS / GLARE (all Visualizers)IMPORTANTReflections can appear only in the bottom half of the working surface, where the light is reflected dire

Komentáře k této Příručce